Technical Parameter
|
Model and specification |
500L |
1000L |
2000L |
3000L |
4000L |
5000L |
6000L |
8000L |
10000L |
|
Vessel design pressure |
0.09 Mpa |
||||||||
|
Jacket design pressure |
0.3 Mpa |
||||||||
|
Vessel design temperature |
105 ℃ |
||||||||
|
Jacket design temperature |
143 ℃ |
||||||||
|
Heating area |
1.5 ~ 20㎡ |
||||||||
|
Condensing area |
4 ~ 30㎡ |
||||||||
|
Cooling area |
0.5 ~ 3㎡ |
||||||||
|
Steam consumption |
285 ~ 1600 Kg/h |
||||||||
|
Cooling water consumption |
2.1 ~ 6.7 T/h |
||||||||
|
Note: The above parameters are approximate data and will be customized according to the customer's design specifications. |
|||||||||
Multi-Claw System vs. Traditional Bolt Extraction Tanks
|
Key Buying Factor |
Traditional Manual Flange Extractor |
Tanlet Multi-Claw Batch Extractor |
|
Slag Discharge Efficiency |
Manual bolt unfastening, heavy labor. |
Automated Multi-Claw Release with pneumatic bottom door opening. |
|
High Pressure & Thermal Safety |
Uneven bolt torque risks solvent gas leakage at 0.2+ MPa. |
Multi-point synchronous claws deliver uniform clamping force up to 0.3+ MPa design pressure. |
|
Filtration & Anti-Clogging |
Bottom-only mesh often gets blinded by fibrous herbs/roots. |
Dual Side & Bottom Filtration: Prevents paste formation and liquid trapping. |
|
Sanitary & CIP Performance |
Hard-to-clean dead corners around manual swing bolts. |
Fully flushable multi-claw interface with 360° CIP rotary spray balls. |
Multi-Point Synchronous Pneumatic Claw Locking
Interlocked pneumatic safety sensors prevent door opening when internal tank pressure is detected.
Long-life high-temperature fluoro-rubber (FKM/PTFE) gaskets guarantee zero solvent/steam escape during jacketed heating.
Dual Side-Wall & Bottom Screen Filtration
Designed specifically for viscous or fine herbal slurry that typically clogs bottom filters.
Side-mounted stainless steel wedge-wire strainers allow unhindered miscellas drainage even when heavy herbal residue settles at the bottom.
Multi-Functional Process Versatility
Atmospheric Decoction & Forced Circulation: Dynamic pump-driven circulation can increase the mass transfer rate and shorten the extraction time.
Solvent & Alcohol Extraction: Explosion-proof design for volatile solvent recovery under vacuum or pressure.
Essential Oil Separation: Top-mounted condenser and oil-water separator setup for aromatic plant oils.
Water or Organic-Solvent Extraction
The Multi-Claw Extractor can be configured for different extraction media based on your process requirements:
Water extraction:Heating + circulation + filtration
Heat-sensitive materials:Controlled/staged heating
Organic-solvent extraction:Closed process configuration according to solvent requirements
High-pressure extraction:Pressure-rated vessel and mechanical locking system
Extract requiring further separation:Condenser, cooler, separator, and filtration can be integrated
The final configuration is selected according to solvent properties, operating temperature, pressure, and applicable safety requirements – we help you confirm the right setup for your process.

Quality Assurance & Manufacturing Standards
Material Certification
All contact parts made from SS304 or SS316L with full EN 10204 3.1 Material Test Reports (MTR).
Pressure Vessel Safety
Manufactured under ASME / PED standards with 100% NDT (Radiographic/Ultrasonic) weld testing and hydrostatic pressure testing.
GMP Validation Documentation
Complete IQ/OQ protocol packages provided upon request for pharmaceutical client audits.
FAQ
Q:What is the main advantage of a Multi-Claw Extractor?
A:Its main design advantage is the mechanical multi-point locking system, which provides stable discharge-door locking and sealing for demanding extraction processes.
Q:Can it use organic solvents?
A:Yes. It can be configured for compatible organic-solvent extraction. Solvent type, operating temperature, pressure and safety requirements should be confirmed before equipment design.
Q:How do you prevent filter blockage?
A:The equipment can use bottom heating, backwash and side filtration to reduce residue accumulation and improve extract-liquid discharge.
Q:Can the extractor be connected to other equipment?
A:Yes. It can be integrated with condensers, coolers, oil-water separators, filters, circulation pumps and downstream concentration or separation equipment.
Q:What is the production lead time?
A:The standard production lead time is about 30-45 days after deposit confirmation and technical specifications approval. The final delivery date is confirmed in the purchase contract.
Q:What payment methods do you accept?
A:The standard payment method is T/T (bank transfer). L/C is also available for qualified orders and can be confirmed during contract negotiation.
Hot Tags: multi-claw extractor, China multi-claw extractor manufacturers, suppliers, factory, Basket Type Extractor, extractor tank, Multi Claw Extractor, Multi Functional Extractor, Percolation Tank