Fermentation Tank
The Fermentation Tank is designed for main fermentation processes where stable temperature, mixing, aeration and hygienic conditions need to be maintained throughout the batch. Its configuration is determined by the actual fermentation process rather than vessel capacity alone.
Key Technical Reference
|
Item |
Technical Reference |
|
Internal Surface Finish |
Ra < 0.4 μm |
|
Small-Scale Sterilization |
115°C / 30 min, applicable to 5 L units |
|
Larger Tank Sterilization |
121°C / 30 min steam sterilization, reference condition |
|
Pressure During Operation |
Approx. 0.05 MPa, depending on process |
|
Process Control |
Temperature, pH, agitation, DO |
|
Product-Contact Material |
SS304 / SS316L, according to process |
Start With the Fermentation Process, Not the Tank Size
|
Process information |
Why it matters |
|
Batch / working volume |
Determines usable fermentation capacity |
|
Fermentation temperature |
Determines heating and cooling requirements |
|
Broth viscosity |
Affects agitator selection |
|
Aeration demand |
Determines air distribution configuration |
|
Foaming tendency |
Affects headspace and foam-control provisions |
|
Sterility requirement |
Influences tank connections and cleaning/sterilization design |
Control the Conditions That Affect Fermentation
Heating or cooling is configured according to the required fermentation temperature and heat load.
A pH electrode and control interface can be provided where pH adjustment is required.
Agitator speed and impeller configuration are selected according to broth characteristics and mixing requirements.
DO monitoring can be integrated for aerobic fermentation, with electrode calibration performed under specified agitation and aeration conditions.
Sterilization According to Tank Scale
For applicable 5 L small-scale fermentation tanks, the prepared medium can be sterilized in an external autoclave, with 115°C for 30 minutes as a reference condition.
For larger fermentation tanks, steam sterilization at 121°C for 30 minutes can be used as a reference sterilization condition, subject to the actual process and equipment configuration.
Hygienic Design Is Part of the Fermentation Process
Product-contact surfaces can be polished to Ra < 0.4 μm to support cleaning and sterilization and reduce material retention.
Other hygienic considerations include:
- SS304 or SS316L product-contact material
- Smooth internal surfaces
- Drainable vessel design
- Sanitary process connections
- Sampling arrangement
- CIP connections
- SIP configuration where required
Process Integration
The main fermentation tank is normally connected with upstream seed preparation and downstream processing. Its inlet, outlet, transfer line and instrumentation should therefore be considered together with the surrounding equipment.
A typical process connection can be arranged as:
Seed Tank → Fermentation Tank → Transfer / Downstream Processing
The connection layout can be adapted according to the required transfer method, pipeline arrangement and cleaning requirements.
Match the Tank to Your Fermentation Medium
The fermentation medium also affects material selection, discharge arrangement and cleaning requirements. Media with solids, higher viscosity or specific hygiene requirements may require different vessel and connection configurations.
Before selection, buyers should confirm:
Solids content → Discharge characteristics → Material compatibility → Cleaning method
What to Provide for a Fermentation Tank Quotation
To configure the tank correctly, buyers should provide:
- Required: Working volume, fermentation medium and operating temperature.
- Useful for detailed configuration: aeration requirement, agitation conditions, pH range, DO requirement, sterilization method, heating/cooling utility and existing process connections.
FAQ
Q: How is fermentation tank working volume determined?
A: It should be based on the actual batch volume, with sufficient headspace for aeration, foaming and normal operation.
Q: How is the agitator selected?
A: Agitator configuration depends on broth viscosity, solids content, aeration and required mixing intensity.
Q: Can the tank provide both heating and cooling?
A: Yes. The heat-transfer arrangement can be configured according to the required fermentation temperature and process duty.
Q: What does Ra < 0.4 μm mean for the tank?
A: It indicates a smooth internal surface finish that supports cleaning and sterilization and helps reduce material retention.
Q: Can the tank be configured for aerobic fermentation?
A: Yes. Aeration and DO monitoring can be incorporated where required, with the air distribution and agitation configuration matched to the fermentation process.
Q: Can the fermentation tank be connected to an existing CIP system?
A: Yes. CIP connections can be incorporated according to the existing cleaning circuit, connection size and required cleaning arrangement.
Hot Tags: fermentation tank, China fermentation tank manufacturers, suppliers, factory, fermentation, Fermentation Tank, Seed Tank
Send Inquiry