Shell and Tube Heat Exchanger
The Shell And Tube Heat Exchanger is designed for indirect heat transfer between two process fluids. One medium flows through the tubes while the other passes through the shell side, allowing heating, cooling or heat recovery without direct contact between the fluids.
The exchanger is configured according to heat-transfer duty, fluid properties, operating pressure and temperature, allowable pressure drop, material compatibility and installation requirements.
Typical Reference Configurations
The following are typical reference configurations for preliminary selection, not fixed standard models. Final specifications should be confirmed according to thermal duty, fluid properties and operating conditions.
|
Heat Transfer Area |
Shell Diameter |
Tube Diameter |
Tube Quantity |
Reference Length |
|
4 m² |
DN300 |
25 mm |
55 |
950 mm |
|
6 m² |
DN300 |
25 mm |
55 |
1400 mm |
|
8 m² |
DN350 |
25 mm |
85 |
1200 mm |
|
10 m² |
DN350 |
25 mm |
85 |
1500 mm |
|
12 m² |
DN550 |
25 mm |
187 |
1350 mm |
|
20 m² |
DN550 |
25 mm |
192 |
1500 mm |
|
30 m² |
DN600 |
25 mm |
226 |
2000 mm |
Tube Side and Shell Side
Tube Side: The tube side can be assigned to the fluid according to temperature, pressure, fouling tendency and material compatibility.
Shell Side: The shell side provides the flow path around the tube bundle. Baffles can guide the shell-side flow across the tubes, helping reduce flow short-circuiting and improve heat-transfer performance.
Materials / Design / Inspection
- Product-contact materials are selected according to the process medium, operating temperature, pressure and corrosion conditions.
- The equipment can be reviewed for tube arrangement, shell-side flow, connections, cleaning access and overall installation dimensions before fabrication.
- Manufacturing inspection can include material verification, welding and assembly inspection, dimensional checks, connection inspection and applicable pressure testing.
Maintenance & Cleaning
Maintenance requirements depend mainly on fouling characteristics, fluid composition and cleaning methods.
Before ordering, buyers should confirm:
- Expected deposit type
- Required cleaning frequency
- Mechanical or chemical cleaning method
- Tube-side access requirements
- Inspection requirements for tubes and connections
Changes in pressure drop or heat-transfer performance during operation may indicate fouling and the need for inspection or cleaning.
Quotation Data Sheet
|
Information |
Details to Provide |
|
Heat-transfer duty |
Heating, cooling or heat-recovery duty |
|
Tube-side fluid |
Fluid name and composition |
|
Shell-side fluid |
Fluid name and composition |
|
Flow rate |
Normal and/or maximum flow rate |
|
Inlet temperature |
Tube-side and shell-side |
|
Outlet temperature |
Tube-side and shell-side |
|
Operating pressure |
Tube-side and shell-side |
|
Allowable pressure drop |
Tube-side and shell-side |
|
Fluid viscosity |
If applicable |
|
Corrosiveness |
Fluid composition or corrosion information |
|
Fouling tendency |
Expected deposits or fouling conditions |
|
Material requirement |
Required product-contact material, if specified |
|
Connections |
Size, type and orientation |
|
Installation space |
Available length, width, height and access space |
|
Cleaning requirement |
Mechanical, chemical or other method |
|
Quantity |
Required equipment quantity |
FAQ
Q: Is the listed heat-transfer area a fixed equipment specification?
A: No. The 4–30 m² configurations are typical reference options, not fixed standard models. Final heat-transfer area and equipment dimensions should be confirmed according to the process requirements.
Q: Can the heat exchanger replace an existing unit?
A: Yes. For replacement projects, the existing heat-transfer duty, connection details, operating conditions and available installation space should be provided for configuration review.
Q: Can the tube-side and shell-side connections be customized?
A: Yes. Connection size, type, orientation and location can be reviewed according to the existing process piping and installation requirements.
Q: Can the material be specified according to the process fluid?
A: Yes. Product-contact materials can be selected according to fluid composition, temperature, pressure and corrosion conditions.
Q: Can the exchanger be designed for limited installation space?
A: Yes. The overall dimensions and connection arrangement can be reviewed according to the available installation space and required maintenance access.
Q: What information is required for a quotation?
A: Key information includes heat-transfer duty, fluid types, flow rates, inlet and outlet temperatures, operating pressure, allowable pressure drop, fluid properties, connection requirements and installation conditions.
Hot Tags: shell and tube heat exchanger, China shell and tube heat exchanger manufacturers, suppliers, factory, heat exchanger condenser, Shell and Tube Heat Exchanger
Send Inquiry