Single-effect External Circulation Vacuum Evaporator
The Single-Effect External Circulation Vacuum Evaporator is designed for vacuum concentration and solvent recovery where a simple single-effect process, external circulation and controlled boiling conditions are required. It is particularly suitable for alcohol or solvent-containing liquids that require concentration and recovery in the same process.
Key Technical Parameters
|
Parameter |
Reference |
|
Evaporation Capacity |
500 / 1000 / 2000 / 2500 kg/h, water basis |
|
Steam Pressure |
0.25 MPa |
|
Steam Consumption |
Approx. 550 / 1100 / 2200 / 2750 kg/h |
|
Cooling Water Consumption |
35 / 70 / 140 / 175 T/h |
|
Vacuum Degree |
-0.06 to -0.095 MPa |
|
Gas Throughput |
165 / 280 / 400 / 600 m³/h |
|
Overall Dimensions |
Approx. 3.42×1.10×4.40 to 5.15×1.60×5.30 m |
Key Configuration Advantages
Simple Single-Effect Process
A straightforward evaporation process for applications where simple operation is preferred over maximum steam economy.
External Circulation Heating
The process liquid circulates through an external heating loop before returning to the evaporation chamber, providing a defined circulation path and controlled heat transfer.
Vacuum Concentration
Reduced pressure lowers the boiling temperature, helping limit thermal exposure during concentration and solvent recovery.
Alcohol & Solvent Recovery
Reference performance indicates recovered alcohol concentrations of approximately 70–85%, with alcohol loss below 5%, depending on feed composition and operating conditions.

Equipment Configuration
The system typically includes:
- Heating chamber
- Evaporation chamber
- Vapor-liquid separator
- Condenser and cooler
- Receiving tank
- Circulation piping and valves
Suitable Process Scenarios
Typical scenarios include:
Alcohol-containing extracts requiring concentration and recovery of ethanol or other volatile components.
Pharmaceutical process liquids where solvent recovery is required during vacuum concentration.
Botanical extracts requiring removal of water or solvent under reduced pressure.
Chemical process streams containing recoverable solvents that can be condensed and collected.
Process & Engineering Support
Equipment selection should be based on feed composition, flow rate, initial and target concentration, boiling characteristics, solvent content, viscosity and required evaporation capacity.
For project-based orders, these process conditions can be reviewed to determine heating capacity, circulation requirements, condenser duty, vacuum conditions and utility requirements before fabrication.
Information Required for Quotation
For process sizing, provide:
- Feed flow rate
- Initial and target concentration
- Feed temperature
- Viscosity and solids content
- Solvent or alcohol composition
- Required evaporation capacity
- Available steam pressure
- Cooling-water temperature and flow
- Required vacuum condition
- Product characteristics and heat sensitivity
FAQ
Q: Is this evaporator suitable for alcohol-containing liquids?
A: Yes. The vacuum evaporation process can be used for alcohol-containing liquids where concentration and recovery of ethanol or other volatile components are required. Final recovery performance depends on feed composition and operating conditions.
Q: What evaporation capacity can this model handle?
A: Reference models provide evaporation capacities of 500, 1000, 2000 and 2500 kg/h on a water basis. Actual capacity should be confirmed according to the feed properties, target concentration and required operating conditions.
Q: Why use external circulation for vacuum evaporation?
A: External circulation provides a defined heating loop for the process liquid and allows heat transfer and circulation conditions to be considered separately from the evaporation chamber.
Q: What vacuum level is used during operation?
A: The reference vacuum range is approximately -0.06 to -0.095 MPa. The actual operating vacuum should be determined according to the feed boiling characteristics, solvent content and required evaporation conditions.
Q: Can alcohol or other solvents be recovered during concentration?
A: Yes. The system can incorporate a condenser, cooler and receiving tank to collect condensed alcohol or other recoverable volatile components. Recovery performance depends on the solvent properties and process conditions.
Q: What feed data is required for equipment sizing?
A: Key information includes feed flow rate, initial and target concentration, temperature, viscosity, solids content, solvent composition, required evaporation capacity and available steam, cooling-water and vacuum conditions.
Hot Tags: single-effect external circulation vacuum evaporator, China single-effect external circulation vacuum evaporator manufacturers, suppliers, factory, Balanced Double Effect Evaporator, concentrator evaporator, Heat Pump Doulbe Effect Evaporator, MVR Rising Film Evaporator, Single effect External Circulation Vacuum Evaporator, Wiped Thin Film Evaporator
Send Inquiry